Worcester Bosch boiler fault codes: what they mean and what to do

A Worcester Bosch fault code tells you why the boiler has stopped. The one people see most is EA 227, which means the boiler tried to light but saw no flame. Others point to low water pressure (CE 207 or 1017) or the boiler getting too hot (224). You can often clear these with safe checks and one reset. If the code keeps coming back, a Gas Safe engineer needs to find the cause.

Updated 08/11/2026 · Express Contractors

This guide explains the Worcester Bosch codes people see most, what you can safely check, and when to stop. If a code won't clear, you'll need a boiler repair from a Gas Safe engineer. We repair all makes, including Worcester Bosch. This guide is part of our common boiler problems series. Got a Vaillant instead? See our guide to Vaillant boiler fault codes. Got an Ideal? See what Ideal codes mean.

How do Worcester Bosch fault codes work?

Most Worcester boilers with a screen show a code in two parts, such as EA and 227. The letters are the type of fault. The three numbers are the cause. Newer Greenstar 4000 and 8000 boilers show a number with a short line of text, such as "Fault 1017, System pressure too low".

Older models without a screen flash a light instead. On many of them, the reset button flashes and the blue light flashes too. Codes can differ between models, so check the manual for your boiler. Worcester puts its manuals on its own website if you've lost yours.

Worcester's manuals split faults into two kinds. A blocking fault stops the boiler for a while, and it starts again by itself once the problem clears. A locking fault keeps it off until you press reset. That's why some codes vanish on their own and others don't.

Worcester fault codes at a glance

EA 227, CE 207 and 1017 are the codes you can most often clear yourself. Find your code below, then jump to its section. "Reset once" means press the reset button one time, and call an engineer if the code comes back.

CodeWhat it meansCan I fix it?
EA 227The boiler tried to light, but no flame was seenOften. Check the gas and the condensate pipe, then reset once.
EA 229The flame went out while the boiler was runningSame checks as EA 227, then reset once.
CE 207 or 1017Water pressure too lowOften. Top up the pressure.
E9 224 or 224The boiler got too hot, so a safety cut-out stopped itCheck the pressure and reset once. If it returns, call an engineer.
A1 281The pump is stuck, or running with air in itCheck the pressure. If it returns, call an engineer.
2951The flame went out too many times (Greenstar 4000 and 8000)Check the gas and the condensate pipe, then reset once.
C6, C7, D1, E2, E9 219, F0, F7, FA, FDA fan, sensor, flame, overheat or circuit board fault, or a power cut (FD)Only FD: reset once after a power cut. The rest need a Gas Safe engineer.

Safety first

Smell gas? Open doors and windows. Don't use light switches or anything that could spark. Turn the gas off at the meter if you can do it safely. Then go outside and call the National Gas Emergency number on 0800 111 999.

Headaches, dizziness, sickness or a lazy yellow flame? These can be signs of carbon monoxide (CO), a poison gas you can't see or smell. Turn the boiler off, open windows, get everyone outside and call 0800 111 999. See a doctor if anyone feels unwell. Our carbon monoxide advice has more.

Never open the boiler case. Only a Gas Safe registered engineer should take the cover off a gas boiler. The checks in our guides are all ones you can do from the outside.

What does EA 227 mean on a Worcester boiler?

EA 227 means the boiler tried to light, but it couldn't see a flame. Worcester boilers try four times, then lock out. A lockout is when the boiler shuts down for safety and waits for a reset. A gas supply problem or a frozen condensate pipe is a common cause.

  1. Check that your gas hob or cooker lights. If it does, gas is reaching the house.
  2. If you have a prepayment meter, check it has credit.
  3. On a freezing day, check the condensate pipe outside. That's the small plastic pipe that drains waste water from the boiler. If it's iced up, pour warm water over it. Never use boiling water. Only do this if the pipe is at ground level. Worcester says never try to thaw one that's up high.
  4. From the ground, look at the flue outside. The flue is the pipe that takes fumes away. Check nothing is blocking it.
  5. Reset the boiler once, and give it two or three minutes.

Here's something many guides miss. Worcester's installer manual lists a blocked condensate trap as a cause of EA 227, as well as a frozen pipe. The trap sits inside the boiler and collects the waste water. So if EA 227 comes back after you've thawed the pipe, stop resetting it. The trap may need an engineer to clean it. Our guide to a frozen condensate pipe shows how to thaw one safely.

If the gas works and the pipe is clear, the cause is likely inside the boiler. It could be the ignition, the gas valve or the flue. If nothing in the house gets gas, contact your gas supplier. See also our guide to a boiler that won't turn on.

What does EA 229 mean on a Worcester boiler?

EA 229 means the flame lit, but it went out while the boiler was running. Worcester lists two common causes. One is water backing up inside from a blocked condensate trap. The other is strong wind blowing into the flue.

Do the same checks as EA 227. Look at the condensate pipe on a cold day and the flue on a windy one. Then reset once. If EA 229 keeps coming back, an engineer needs to check the trap, the flue and the flame sensor. If your boiler cuts out often, our guide to a boiler that keeps turning off explains more.

What do CE 207 and fault 1017 mean on a Worcester boiler?

CE 207 and 1017 both mean the water pressure in your heating is too low. CE 207 shows on boilers like the Greenstar CDi. Fault 1017 shows on the Greenstar 4000 and 8000. Topping up the pressure usually clears it.

Check the gauge or the pressure screen with the heating off and cool. It should read about 1 to 1.5 bar. "Bar" is the unit the gauge uses. Worcester says top it up if it's under 0.8 bar. Worcester boilers use one of two ways to let water in. Some have a filling key that clips in under the boiler. Others have a filling loop, a short hose with a tap at each end.

  1. Turn the heating off and let the boiler cool.
  2. Fit the filling key, or connect the filling loop. Your manual shows where it goes on your model.
  3. Open the valve slowly and watch the gauge.
  4. Close it once the gauge reads about 1 to 1.5 bar.
  5. Take the filling key out, or disconnect the loop, as your manual says.

Our guide to a boiler losing pressure has more detail. If the pressure drops again within days, water is getting out somewhere. That could be a leak, a worn pressure relief valve or a tired expansion vessel. The expansion vessel is a small tank in the boiler that soaks up pressure as the water heats. If the gauge reads fine but the code stays, the pressure sensor may have failed. All of these need a Gas Safe engineer.

What does 224 mean on a Worcester boiler?

224 means the boiler got too hot, so a safety thermostat stopped it. On many models it shows as E9 224. The heat isn't getting away from the boiler fast enough. Low pressure, air in the system and a pump that isn't running are common causes.

Check the pressure first, and top it up if it's low. Make sure your radiator valves are open. If radiators are cold at the top, they may have air in them. Turn the heating off, bleed them, then check the pressure again. Worcester warns against bleeding radiators with the heating on. Our guide to cold radiators shows how. Then reset once.

If 224 comes back, an engineer needs to check the pump, the thermostat and the pipes. Sludge can block the flow too. Sludge is black dirt that builds up inside old radiators and pipes.

What does A1 281 mean on a Worcester boiler?

A1 281 means the pump is stuck, or it's running with air in it. Worcester says this usually means there's little or no water in the system. The pump pushes hot water round your radiators.

Check the pressure and top it up if it's low. A1 is a blocking fault, so the boiler may start again by itself once the water is back. If A1 keeps coming back with the pressure fine, the pump needs an engineer. It sits inside the case.

What does 2951 mean on a Worcester boiler?

2951 shows on Greenstar 4000 and 8000 boilers. It means the flame has gone out too many times, so the boiler has locked out. It often follows another code, 2950. That one means no flame was seen after starting, and the boiler tries again by itself.

Check the gas hob and any prepayment meter. On a cold day, check the condensate pipe. Then reset once. If 2951 comes back, an engineer needs to look. Worcester lists causes such as the gas pressure dropping, or a badly placed flue or condensate pipe. The boiler keeps a fault history, so the engineer can see which codes led up to it.

What do other Worcester fault codes mean?

Most other Worcester codes point to a part inside the boiler, so they need a Gas Safe engineer. There's nothing safe for you to check, apart from a reset after a power cut.

  • C6 215 and C6 216: the fan is running too fast or too slow.
  • C7 214: the fan isn't running.
  • D1 240 and D1 241: a temperature sensor on the return pipe is wet, damaged or unplugged.
  • E2 222 and E2 223: a fault with the flow temperature sensor.
  • E9 219: the main heat exchanger got too hot. The heat exchanger is the part that heats the water.
  • F0: an internal fault, usually the circuit board.
  • F7 228 and FA 306: a flame was seen when the burner should be off. Turn the boiler off and don't keep resetting it.
  • FD 231: the power was cut. Reset once. Our guide to a boiler after a power cut may help.

We've only listed codes we could confirm in Worcester's own manuals. If your code isn't here, check your manual, or note it down and give it to the engineer.

How do I reset a Worcester Bosch boiler?

Press the reset button briefly, once. On a Greenstar 4000 or 8000, use the arrow keys until Reset shows on the screen, then select it. Give the boiler two or three minutes to start again.

If the same code comes back, stop. The boiler is protecting itself. Worcester's own manual says some codes can't be cleared by a simple reset. It also says no fault is found on over 30% of its engineers' visits. So the simple checks above are always worth doing first.

Which Worcester Bosch boiler do I have?

The model name is usually on the front of the boiler, or on a sticker called the data label. Common Worcester models include the Greenstar i, Si Compact, CDi Compact, CDi Classic, Ri, 2000, 4000 and 8000. Older homes may have an older i Junior or Greenstar HE. Write the model down with the code. Some codes differ by model.

Do you need a new boiler if your Worcester shows a fault code?

Usually not. Most Worcester fault codes come from a part that can be repaired or replaced. A fan, sensor, pump or ignition part is a normal repair. Low pressure or a frozen pipe may need no parts at all.

A new boiler can be worth weighing up when:

  • the main heat exchanger has failed on an older boiler
  • the boiler is well over 10 years old and keeps showing different codes
  • the parts for your model have stopped being made

We'll weigh up the repair against the boiler's age with you, and tell you plainly which makes more sense. Our guide to how long a boiler lasts can help you decide. If it's time to replace the boiler, our new boiler page shows how it works, from a free survey to a fixed price. We fit all makes.

When to call a Gas Safe engineer

Call a Gas Safe engineer if a code comes back after your checks and one reset. Also call straight away for any code you can't fix from the outside. By law, only a Gas Safe registered engineer may work on a gas boiler.

  • CE 207 or 1017 returns within days of topping up
  • EA 227, EA 229 or 2951 keeps coming back, even with gas and a clear condensate pipe
  • 224 or A1 281 returns after one reset
  • you see C6, C7, D1, E2, E9 219, F0, F7 or FA
  • you smell burning, or see soot or black marks round the boiler

The code is only a starting point. The engineer first runs a thorough check of the boiler. That finds the fault and the parts needed. We tell you the price before we start any work. See our boiler repair page for the faults we fix.

A yearly boiler service helps stop many of these codes. The engineer cleans the parts that need it, tests the safety devices and checks the system pressure.

Other boiler guides

Worcester code won't clear? Book a boiler repair and we'll find the cause.

Common questions

Bob, the Express Contractors mascot, thinking
How do I reset a Worcester Bosch boiler?

On most Greenstar boilers with a screen, press the reset button briefly, once. On a Greenstar 4000 or 8000, use the arrow keys until Reset shows, then select it. Give it two or three minutes to start. If the same code comes back, stop there. Worcester says some codes can't be cleared by a reset. Read when to stop resetting a boiler.

Why does my Worcester boiler keep showing EA 227?

EA 227 means the boiler tried to light four times and saw no flame. If it keeps coming back, check your gas hob works and any prepayment meter has credit. On a freezing day, check the condensate pipe outside for ice. If none of these is the cause, the ignition, gas valve or condensate trap needs an engineer. Read how to thaw a frozen condensate pipe.

Why is the blue light flashing on my Worcester boiler?

On many Worcester boilers, the blue light glows when the boiler is heating and flashes when there is a fault. If your boiler has a screen, look for a code on it. Older models without a screen flash the reset button instead. Check the pressure, then reset once.

What is the difference between a blocking and a locking fault?

A blocking fault stops the boiler for a short while. It starts again by itself once the problem clears, for example when the water cools down. A locking fault keeps the boiler off until someone presses reset. Worcester manuals list both kinds.

Can I fix a Worcester fault code myself?

Some, yes. You can top up low pressure, check the gas supply, thaw a frozen condensate pipe at ground level and reset the boiler once. These clear many CE 207, 1017 and EA 227 codes. Anything inside the boiler case is for a Gas Safe registered engineer.

What should I tell the engineer about a Worcester fault code?

Give the letters and the number, the boiler model, and what happened before the code appeared. Say if you have already topped up or reset it. The code is only a starting point. On the visit, the engineer first runs a thorough check of the boiler to find the fault and the parts it needs. Book a boiler repair.