TRV not working? How to fix a stuck radiator valve

Most TRV faults are a stuck pin or a worn head. You can check both yourself in a few minutes. Take the head off and press the pin. If it springs back and the radiator heats up, the head is the problem. If the pin won't move, the valve may need replacing.

Updated 15/11/2026 · Express Contractors

A TRV that won't work usually leaves one radiator cold, or stuck on full heat. The checks below are safe to try at home. If the valve needs changing, a plumber can fit a new valve for you. If every radiator is cold, the TRVs aren't the cause, and you may need a boiler repair. This guide is part of our boiler problems series.

What is a TRV and how does it work?

TRV stands for thermostatic radiator valve. It's the dial with numbers on the side of a radiator, and it controls how much hot water goes in. It reacts to the air in the room, so each room can be a different temperature.

The head holds a small amount of wax or liquid. As the room warms up, this swells. It pushes a pin down, which closes the valve and lets less hot water in. When the room cools, the pin rises again. The valve opens, and the radiator warms up.

What are the signs a TRV isn't working?

The main sign is a radiator that ignores the dial. It stays cold when the others are hot, or stays hot even on a low number. Other signs include:

  • you turn the dial, but nothing changes after half an hour
  • the head is cracked, loose or won't turn
  • the radiator is hot on 1 or on the frost symbol
  • water around the valve, or drips under it
What you noticeLikely causeWhat to try
Radiator cold, dial turned upPin stuck downTake the head off and free the pin
Radiator hot on a low numberPin stuck up, or a worn headTest the pin. If it moves freely, fit a new head
Head loose, cracked or won't turnBroken headFit a new head that matches the valve
Water around the valveWorn seal or valve bodyCall a plumber

Should the TRV pin be up or down?

With the head off, the pin should be up. It should press down with light pressure, then spring back up on its own. Up means the valve is open and water can flow. Down means the valve is closed.

A pin stuck down keeps the radiator cold. If the pin is up and moves freely, but the radiator won't turn down, the head is probably worn. It no longer pushes the pin far enough.

How do I free a stuck TRV pin?

Take the head off and gently work the pin up and down until it moves freely. Use light taps and small movements, and never force it. Most stuck pins free up in a few minutes.

  1. Turn the heating off and let the radiator cool down.
  2. Turn the dial to the highest number.
  3. Unscrew the head by hand. Some have a collar to loosen, or a small clip to undo.
  4. Press the metal pin in the middle with your finger.
  5. If it won't move, tap it a few times with the handle of a screwdriver.
  6. If it's still stuck, hold it with pliers and wiggle it very gently.
  7. Push it up and down a few times, until it springs back easily.
  8. Screw the head back on, still set to the highest number.
  9. Turn the heating on and check the radiator warms up.

Don't pull hard on the pin. It can snap, or the seal around it can start to leak. Don't put oil on the plastic thread of the head either. Taking the head off on its own shouldn't let any water out.

Safety first

Smell gas? Open doors and windows. Don't use light switches or anything that could spark. Turn the gas off at the meter if you can do it safely. Then go outside and call the National Gas Emergency number on 0800 111 999.

Headaches, dizziness, sickness or a lazy yellow flame? These can be signs of carbon monoxide (CO), a poison gas you can't see or smell. Turn the boiler off, open windows, get everyone outside and call 0800 111 999. See a doctor if anyone feels unwell. Our carbon monoxide advice has more.

Never open the boiler case. Only a Gas Safe registered engineer should take the cover off a gas boiler. The checks in our guides are all ones you can do from the outside.

Why do TRVs stick after the summer?

TRV pins often stick because they haven't moved for months. Over the summer the pin sits still, and scale or dirt in the water can grip it. Drayton, a maker of TRVs, says sticking can happen when the valves aren't used over the summer.

So the first cold week is when many people find a radiator that won't heat. It helps to check each TRV before the cold weather starts, so you can free a stuck pin early. If the whole heating system won't start after the warm months, see our guide to heating that won't come on after the summer.

What number should my TRV be on?

The numbers are comfort steps, not exact degrees. A good starting point is about 3 in living rooms and 2 to 3 in bedrooms. Then leave it alone for a day and see how the room feels.

  • The scale varies by maker, so check the booklet if you have it.
  • A higher number won't heat the room faster. It only lets the room get warmer before the valve closes.
  • The frost symbol (*) keeps the room just above freezing.
  • The Energy Saving Trust says to use the lowest setting that keeps the room comfortable.

Don't fit a TRV in the room with your main room thermostat, or leave that one fully open. If both try to control the same room, they can fight each other. The boiler may then switch off too early, and the rest of the house stays cool.

How do I replace a TRV head?

You can replace a TRV head without draining anything. The valve body holds the water, and the head just screws on top. It's a fair job to do yourself.

The main thing is to buy a head that fits your valve. Not every head fits every body, because makers use different threads. Many use a common size, often marked M30 x 1.5. Some brands need their own head, or an adapter. The maker's name is often printed on the valve body or the old head.

  1. Set the new head to its highest number before fitting it.
  2. Unscrew the old head.
  3. Line the new head up over the pin.
  4. Screw it on by hand only. Don't use tools on the plastic.
  5. Turn it to the number you want and check the radiator over the next hour.

Smart TRVs with batteries work the same way. If one stops working, try new batteries first.

When does the whole valve need replacing?

The whole valve needs replacing if the pin won't free, the seal leaks or the body is badly corroded.Changing the valve body is a job for a plumber or heating engineer. The water has to be drained down first, or the pipe frozen with a special kit.

After the new valve goes on, the system is refilled and the radiators are bled. An inhibitor is added back to the water. This is a liquid that slows down rust and sludge. A combi or system boiler also needs the pressure topping up.

We fit new TRVs and free stuck valves as part of our plumbing and radiator valve work. A TRV can also be swapped for a plain manual valve. But if you plan to replace your boiler later, keep in mind the room controls rule below.

Is it the TRV, the boiler or something else?

If only one radiator has a problem, it's almost always the valve, trapped air or sludge. If every radiator is cold, the TRVs aren't to blame. That points to the boiler, the pump or a zone valve.

If the water inside looks black when you bleed a radiator, sludge may be sticking the pins too. A system clean washes it out.

Do you need a new boiler if a TRV isn't working?

Almost never. A TRV is a small, cheap part on one radiator. When it fails, the boiler is usually fine. Freeing the pin or fitting a new head or valve fixes the problem.

There is one link to know about. When a boiler is replaced in England, the Building Regulations now ask for temperature control in each room. That usually means TRVs on the radiators. So if you're planning a new boiler anyway, old or faulty valves can be sorted at the same time.

When to call a plumber or Gas Safe engineer

Call for help if the pin won't free, or the valve is leaking. Anything that means draining the system is best left to a professional. Call a Gas Safe engineer if the problem is the whole heating system.

  • the pin won't move after gentle taps
  • water is dripping from the valve
  • the valve body needs changing
  • several radiators won't heat, even with the dials up
  • every radiator is cold with the boiler on
  • the boiler shows a fault code or keeps cutting out

For valves, see our plumber page. For the boiler, an engineer first runs a thorough check of the boiler and the heating system. That finds the fault and the parts needed. See our boiler repair service for the faults we fix. A yearly boiler service can also spot worn parts early.

Other boiler guides

Valve still stuck? Get a plumber to change it. Whole house cold? Book a boiler repair and we'll find the cause.

Common questions

Bob, the Express Contractors mascot, thinking
Should a TRV pin be up or down?

With the head off, the pin should be up. Press it gently and it should go down with a little resistance, then spring back up. A pin that stays down keeps the valve shut, so the radiator stays cold. Gentle taps can often free it.

Can I change a TRV head without draining the system?

Yes. The head is only the dial on top, and the valve body underneath holds the water in. So you can unscrew the head and fit a new one with the heating full. Changing the valve body is different. That means draining the system or freezing the pipe.

Does it matter which side of the radiator the TRV goes on?

Many modern TRVs work in both directions, so they can go on either pipe. Older or one-way valves have an arrow on the body that shows which way the water should flow. A one-way valve fitted the wrong way round can hum or bang. Check for the arrow, or ask us. What heating noises mean.

Do I need TRVs on every radiator?

You don't have to add them to an existing system, but they help save energy. When a boiler is replaced in England, each room needs its own temperature control. TRVs are usually the easiest way. The room with the main thermostat is normally left without one.

Why is my radiator hot when the TRV is on 1?

The pin is probably stuck up, or the head is worn and no longer pushes the pin down. Take the head off and press the pin. If it moves freely and springs back, the head is the problem. A new head usually fixes it.

How long do TRVs last?

There is no fixed lifespan. Many last for years. The wax or liquid in the head can wear out over time, so it stops reacting. Pins stick more often in hard water areas or in systems full of sludge. A worn head is easy to change.

Bob, the Express Contractors mascot, looking puzzled at a boiler screen

TRV still not working?

Call us if the pin won't free or the valve leaks. We fit new TRVs and valves. If all your radiators are cold, we'll check the boiler and the heating system to find the fault.