Vaillant boiler fault codes: what they mean and what to do

A Vaillant fault code starts with F and tells you why the boiler has stopped. The most common are F22 (low water pressure), F28 (the boiler didn't light) and F29 (the flame went out). You can often clear these with safe checks and one reset. If the code keeps coming back, a Gas Safe engineer needs to find the cause.

Updated 04/11/2026 · Express Contractors

This guide explains the Vaillant codes people see most, what you can safely check, and when to stop. If a code won't clear, you'll need a boiler repair from a Gas Safe engineer. We repair all makes, including Vaillant. This guide is part of our common boiler problems series.

Older Vaillant boilers show codes with two numbers, like F.22. Newer ecoTEC plus boilers use three, like F.022. They mean the same thing. So F22, F.22 and F.022 are all the same fault.

Vaillant fault codes at a glance

F22, F28 and F29 are the codes you can most often clear yourself. Find your code below, then jump to its section. "Reset once" means press the reset button one time, and call an engineer if the code comes back.

CodeWhat it meansCan I fix it?
F22Water pressure too lowOften. Top up the pressure, then reset once.
F75No pressure change seen when the pump startsCheck the pressure and reset once. If it returns, call an engineer.
F28The boiler tried to light, but no flame was seenCheck the gas and the condensate pipe, then reset once.
F29The flame went out and wouldn't relightSame checks as F28, then reset once.
F27A flame was sensed with the burner offNo. Turn the boiler off and call an engineer.
F20, F23, F83Overheating, or water not moving round properlyCheck the pressure and reset once. If it returns, call an engineer.
F00, F01, F61, F62, F63, F76A sensor, gas valve or circuit board faultNo. These need a Gas Safe engineer.
S codesStatus messages, not faultsUsually nothing to do.

Safety first

Smell gas? Open doors and windows. Don't use light switches or anything that could spark. Turn the gas off at the meter if you can do it safely. Then go outside and call the National Gas Emergency number on 0800 111 999.

Headaches, dizziness, sickness or a lazy yellow flame? These can be signs of carbon monoxide (CO), a poison gas you can't see or smell. Turn the boiler off, open windows, get everyone outside and call 0800 111 999. See a doctor if anyone feels unwell. Our carbon monoxide advice has more.

Never open the boiler case. Only a Gas Safe registered engineer should take the cover off a gas boiler. The checks in our guides are all ones you can do from the outside.

What does F22 mean on a Vaillant boiler?

F22 (shown as F.22 or F.022) means there's too little water in the boiler, or the water pressure is too low. The boiler shuts down to protect itself. Topping up the pressure often clears it.

Check the pressure gauge with the heating off and cool. It should read about 1 to 1.5 bar. "Bar" is the unit the gauge uses. If it's below 1 bar, top it up like this:

  1. Turn the heating off and let the boiler cool.
  2. Find the filling loop. This is the short hose or tap under the boiler that lets mains water in. Your manual shows where it is on your model.
  3. Open the filling loop slowly and watch the gauge.
  4. Close it fully once the gauge reads about 1 to 1.5 bar.
  5. Press and hold the reset button for a few seconds, once.

Our guide to a boiler losing pressure has the full steps. If the pressure drops again within days, water is getting out somewhere. That could be a leak, a worn pressure relief valve or a tired expansion vessel. The expansion vessel is a small tank inside the boiler that soaks up pressure as the water heats. If the gauge reads fine but F22 stays, the pressure sensor may have failed. All of these need a Gas Safe engineer.

What does F75 mean on a Vaillant boiler?

F75 means the boiler didn't sense the pressure change it expects when the pump starts. The pump pushes hot water round your radiators. The cause is often low pressure, air in the boiler, the pump or the pressure sensor.

F75 is not a "pressure too high" code, even though many people search for it that way. On a Vaillant, high pressure shows as S.41. If that's your problem, see our guide to boiler pressure too high.

For F75, check the gauge first. If it's below 1 bar, top it up as shown for F22. If you've just bled your radiators, the pressure has probably dropped, so top up before you reset. Then reset once. If F75 comes back, the pump or the sensor usually needs an engineer. Both are inside the case.

What does F28 mean on a Vaillant boiler?

F28 means the boiler tried to light, but it couldn't see a flame. It stops and locks out. A lockout is when the boiler shuts down for safety and waits for a reset. Gas supply problems and frozen condensate pipes are common causes.

  1. Check that your gas hob or cooker lights. If it does, gas is reaching the house.
  2. If you have a prepayment meter, check it has credit. Running out is a common cause of F28.
  3. On a freezing day, check the condensate pipe outside. That's the small plastic pipe that drains waste water from the boiler. If it's iced up, pour warm water over it, about as hot as a bath. Never use boiling water.
  4. Reset the boiler once.

There's a point here few guides mention. Vaillant's own installer manual says thawing the outside pipe is not enough on its own. Water can back up inside the boiler too. So if F28 comes back after you've thawed the pipe, don't keep resetting it. The trap inside the boiler, which collects that waste water, may need an engineer to clean it. Our guide to a frozen condensate pipe shows how to thaw it safely.

If the gas works, the meter has credit and the pipe isn't frozen, stop there. The cause is likely inside the boiler. It could be the ignition, the gas valve, the flue or the circuit board. The flue is the pipe that takes fumes outside. If nothing in the house gets gas, contact your gas supplier. See also our guide to a boiler that won't turn on.

What does F29 mean on a Vaillant boiler?

F29 means the flame went out while the boiler was running, and it couldn't relight. The causes are much like F28. The gas supply may have stopped, or the condensate pipe may be frozen.

Do the same checks as F28. Check the gas hob, check any prepayment meter, and look at the condensate pipe on a cold day. Then reset once. If F29 keeps coming back, an engineer needs to check the flue, the ignition and the gas valve. If your boiler cuts out often, our guide to a boiler that keeps turning off explains more.

What does F27 mean on a Vaillant boiler?

F27 means the boiler has sensed a flame while the burner should be off. This can point to a gas valve that isn't closing fully, or a fault on the circuit board. Don't try to fix it yourself.

Turn the boiler off and call a Gas Safe engineer. Vaillant also says not to attempt this one yourself. Don't keep resetting it. If you smell gas at any point, follow the safety advice above straight away.

What do F20, F23 and F83 mean on a Vaillant boiler?

These three codes mean the water isn't moving round the boiler as it should. That can make the boiler run too hot. Low pressure, air and a weak pump are common causes.

  • F20: the boiler got too hot, so a safety cut-out shut off the gas.
  • F23: the water coming back to the boiler is much cooler than the water going out.
  • F83: the burner lit, but the water barely warmed up. This often means low water.

Check the pressure and top up if it's low. Make sure your radiator valves are open. If radiators are cold at the top, bleed them, then check the pressure again. Our guide to cold radiators shows how. Then reset once. If the code comes back, the pump, a valve or a sensor needs an engineer.

What do other Vaillant fault codes mean?

Most other Vaillant codes point to a part inside the boiler, so they need a Gas Safe engineer. There's nothing safe for you to check, apart from the gas supply for F54.

  • F00 and F01: a temperature sensor on the water pipes, or its wiring, has a fault.
  • F54: a gas supply fault, often shown with F28 or F29. Mostly on older boilers. Check other gas appliances and your meter.
  • F61: the wording differs by model. Older manuals say a gas valve fault. Newer ones say a control board fault.
  • F62: the flame took too long to go out when the boiler switched off.
  • F63: a fault with the boiler's circuit board.
  • F76: a safety fuse on the main heat exchanger has tripped from overheating. The heat exchanger is the part that heats the water.
  • F80 and F81: only on storage combis, which have a built-in hot water tank. They point to a sensor or charging fault.

Codes differ between Vaillant models, and we've only listed meanings we could confirm from Vaillant's own manuals. If your code isn't here, check your manual, or note it down and give it to the engineer.

What are Vaillant S codes?

S codes are status messages, not faults. They show what the boiler is doing at that moment. Most need nothing from you. On newer models, you only see them in the information menu.

  • S.04: heating is on and the burner is lit.
  • S.08: a short pause after heating, before it lights again. This is normal.
  • S.30: the room thermostat isn't asking for heat. Turn it up if you want heating.
  • S.41: the water pressure is too high. See our pressure too high guide.
  • S.76: on older models, the pressure is too low, so top it up.
  • S.97 and S.98: the boiler is running a short self-test.

How do I reset a Vaillant boiler?

Press and hold the reset button for a few seconds, once. Most Vaillant boilers have it on the front control panel. The boiler should try to start again within a few minutes.

Vaillant's manual for the current ecoTEC plus says to reset no more than three times. We'd say once is enough. A code that comes back means the boiler is protecting itself. Don't reset at all for F27. If the boiler stopped during a power cut, our guide to a boiler not working after a power cut may help.

Which Vaillant boiler do I have?

The model name is usually on the front of the boiler, or on a sticker called the data plate. Common Vaillant models include the ecoTEC plus, ecoTEC pro, ecoFIT pure and ecoFIT sustain. Older homes may still have a turboTEC or turboMAX. Write the model down with the code. It helps the engineer, as some codes differ by model.

Do you need a new boiler if your Vaillant shows a fault code?

Usually not. Most Vaillant fault codes come from a part that can be repaired or replaced. A sensor, pump, electrode or expansion vessel is a normal repair. Low pressure or a frozen pipe may need no parts at all.

A new boiler can be worth weighing up when:

  • the main heat exchanger has failed on an older boiler, for example after an F76 code
  • the boiler is well over 10 years old and keeps showing different codes
  • the parts for your model have stopped being made

We'll weigh up the repair against the boiler's age with you, and tell you plainly which makes more sense. If it's a new boiler, our page on replacing your boiler shows how it works, from a free survey to a fixed price.

When to call a Gas Safe engineer

Call a Gas Safe engineer if a code comes back after your checks and one reset. Also call straight away for F27, or any code you can't fix from the outside. By law, only a Gas Safe registered engineer may work on a gas boiler.

  • F22 returns within days of topping up
  • F28 or F29 keeps coming back, even with gas and a clear condensate pipe
  • F75, F20, F23 or F83 returns after one reset
  • you see F27, F00, F01, F61, F62, F63 or F76
  • you smell burning, or see soot or black marks round the boiler

The code is only a starting point. The engineer first runs a thorough check of the boiler. That finds the fault and the parts needed. We tell you the price before we start any work. See our boiler repair page for the faults we fix.

A yearly boiler service helps stop many of these codes. The engineer cleans the parts that need it, tests the safety devices and checks the system pressure.

Other boiler guides

Vaillant code won't clear? Book a boiler repair and we'll find the cause.

Common questions

Bob, the Express Contractors mascot, thinking
How do I reset a Vaillant boiler?

Press and hold the reset button on the front control panel for a few seconds, then let go. The boiler should try to start again within a few minutes. Reset it once. Vaillant's ecoTEC plus manual says no more than three times. If the same code comes back, the boiler is protecting itself, so call a Gas Safe engineer. Read when to stop resetting a boiler.

What does F22 mean on a Vaillant boiler?

F22 means there is too little water in the boiler, or the water pressure is too low. Check the gauge with the heating off. If it reads below 1 bar, top it up to about 1 to 1.5 bar with the filling loop, then reset once. If it keeps dropping, there is a leak or a worn part to find. Read our guide to a boiler losing pressure.

Why does my Vaillant boiler keep showing F28?

F28 means the boiler tried to light but no flame was seen. If it keeps coming back, check your other gas appliances work and any prepayment meter has credit. In freezing weather, check the condensate pipe outside for ice. If none of these is the cause, a part such as the ignition or gas valve needs an engineer. Read how to thaw a frozen condensate pipe.

Does F75 mean my Vaillant boiler pressure is too high?

No. F75 means the boiler did not sense the pressure change it expects when the pump starts. It is often linked to low pressure, air in the boiler, the pump or the pressure sensor. On Vaillant boilers, high pressure shows as the status message S.41, not F75. Read our guide to boiler pressure that is too high.

Can I fix a Vaillant fault code myself?

Some, yes. You can top up low pressure, check the gas supply, thaw a frozen condensate pipe and reset the boiler once. These sort out many F22, F28 and F29 codes. Anything inside the boiler case is for a Gas Safe registered engineer. Never take the cover off yourself.

What should I tell the engineer about a Vaillant fault code?

Give the code, the boiler model and what happened before it appeared, such as a cold snap or a power cut. Say if you have already topped up or reset it. The code is only a starting point. On the visit, the engineer first runs a thorough check of the boiler to find the fault and the parts it needs. Book a boiler repair.

Bob, the Express Contractors mascot, looking puzzled at a boiler screen

Vaillant code keeps coming back?

Call us to book a boiler repair. We repair all makes, Vaillant included. A Gas Safe registered engineer will find the fault and tell you the price before starting.

Call now · 0121 517 0785